The PocTell® Blood Gas Test Cartridges must be used with the Blood Gas Analyzers for the in vitro quantitative detection of sodium, potassium, ionized calcium, chloride, pH, pCO2, pO2, glucose, lactate, hematocrit, BUN, Crea, ATC, PT/INR, cTnI, and BNP in the whole blood. The product is for professional use only.


Ordering Information
|
Model No. |
Brand |
Pkg/Size |
Sample |
Shelf life |
|
EG10+ |
PocTell® |
25tests/kit |
arterial/venous blood |
8 months |
The PocTell® Blood Gas Test Cartridge use the electrochemical method to measure the concentration of Na+, K+, iCa2+, Cl-, pH, and pCO2 in whole blood samples. The electrochemical sensor on the cartridge consists of a silver/silver chloride electrode with its ion-selective reagent membrane. When the sample is added to the cartridge and comes into contact with the reagent membrane, the ions in the sample can selectively exchange ions with the reagent membrane, which changes the membrane potential due to the difference in ion concentration. The relationship between the concentration and the potential value is obtained based on the conversion of the Nernst equation
Storage Conditions and Expiration Dates
|
Model |
Storage Condition |
Expiration Date |
|
EG10+, EG4+, EL4+, EG9+, EG9-Lac, EG8+, EG7-Ca, EG7-Cl, EG6+, EG5+, EG3+, EC7+, EC6+, EC5+, EC4+ |
Room temperature storage: 4℃-30 ℃ It should be used immediately after opening. |
8 months |
|
Refrigerated storage: 2°C-8°C (no freezing) |
12months |
|
|
CHEM8+, PT/INR, cTnI, BNP, ACT C, ACT K |
Room temperature storage: 4℃-30 ℃ |
4 months |
|
Refrigerated storage: 2°C-8°C (no freezing) |
6 months |
|
|
Blood Gas Control Solutions |
Room temperature storage: 4℃-30 ℃ |
12 months |
Transportation temperature: 2℃-37℃
Reference Range
|
Parameter |
Reference range |
|
|
Arterial blood |
Venous blood |
|
|
pH |
7.350-7.450 |
7.310-7.410 |
|
pO2 (mmHg) |
80-105 |
35-40 |
|
pCO2 (mmHg) |
35.0-45.0 |
41.0-51.0 |
|
Na+ (mmol/L) |
135-146 |
|
|
K+ (mmol/L) |
3.5-5.2 |
|
|
iCa2+ (mmol/L) |
1.10-1.29 |
|
|
Cl- (mmol/L) |
97-109 |
|
|
Glu (mmol/L) |
3.9-6.1 |
|
|
Lac (mmol/L) |
0.50-1.70 |
|
|
Hct (%) |
38-51 |
|
|
Parameter |
Unit |
Reference range |
|
|
Arterial blood |
Venous blood |
||
|
BUN |
mg/dL |
8-26 |
|
|
mmol/L |
2.9-9.4 |
||
|
mg/dL |
17-56 |
||
|
g/L |
0.17-0.56 |
||
|
Crea |
mg/dL |
0.6-1.3 |
|
|
μmol/L |
53-115 |
||
cTnI: 0.00ng/mL (ug/L) to 0.08ng/mL (ug/L).
BNP: no more than 50 pg/mL (ng/L)
PT/ INR: 0.9 -6.0
Operation Instruction

Hot Tags: blood gas test cartridge, China blood gas test cartridge manufacturers, suppliers, factory, blood gas and electrolyte analyzer, Blood Gas Test Cartridge, Poc Blood Gas Analyzer