Inflammatory Test Kit
Your Professional Inflammatory Test Kit Supplier
INNOCHEK BIOTECH CO., LTD, are dedicating in delivering comprehensive, efficient, and innovative POCT solutions to global users. The company was stablished in 2017 and headquartered in Hongkong, is a conglomerate seamlessly integrating R&D, production, registration, sales, and marketing. Leveraging microfluidics and electrochemical technologies, INNOCHEK has successfully developed a diverse range of key products, including blood gas and electrolytes, immunofluorescence, coagulation, and animal diagnostic series.
Why Choose Us
A variety of technology development platforms
Our technology development platform includes dry blood gas, electrolyte, microfluidic dry biochemistry, dry coagulation, and liquid phase fluorescence immunoassay platforms.
Diagnostic reagent
Based on the diversity of technology platforms, successfully developed for the detection of specific biochemical markers in biological samples, such as proteins, enzymes, hormones, etc., to help diagnose diseases.
Software and information systems
Software and information systems for data management, interpretation, and reporting to help physicians analyze and understand test results more effectively.

The HBsAg test kit is a versatile, rapid, and reliable tool for detecting hepatitis B virus infection. Its suite of immunochromatographic, ELISA, and confirmatory assays address diverse clinical needs, from bedside screening to high-throughput laboratory analysis. By providing objective and timely results, this method enhances HBV diagnosis, prevents transmission, and improves patient outcomes. For optimal use, clinicians should interpret test results in conjunction with clinical findings and other laboratory tests (e.g., HBV DNA and liver function tests).
|
Product Name |
HBsAg Test Kit |
Shelf life |
24 months; |
|
Application |
Initial screening for HBsAg infection; |
Storage temperature |
4-30ºC; |
|
Method |
Colloidal gold immunochromatography; |
Lead time |
Within 2 weeks after getting full payment; |
|
Specimen |
Whole blood / serum / plasma; |
Payment method |
By T/T or by made-in-china or by Western Union; |
|
Package details |
25pcs/box; 1000pcs/carton; |
OEM/ODM |
Acceptable; |
Benefits of HBsAg Test Kit
Quick Results
With results in minutes, the HBsAg rapid test is highly beneficial in clinical settings or point-of-care testing where fast decisions are required.
High Sensitivity and Specificity
These kits are designed to offer reliable results, with a high degree of sensitivity for accurate detection of HBsAg.
Ease of Use
The HBsAg rapid test kit is straightforward to use, with minimal equipment needed, making it accessible for a range of healthcare providers.
Cost-Effective
Compared to laboratory tests, rapid kits are relatively affordable and save time and resources.
Early Diagnosis: Early detection of hepatitis B infection can prevent complications and enable timely intervention.
Screening in High-Risk Areas: Healthcare settings, blood donation centers, and places with high HBV prevalence use HBsAg rapid tests for efficient screening.
Pre-Surgical Screening: The test is used to screen for hepatitis B infection prior to surgeries or medical procedures, where HBV transmission could pose risks.
Monitoring of HBV Carriers: For those diagnosed with chronic hepatitis B, HBsAg rapid tests may be used periodically to monitor infection status.

How the HBsAg Test Kit works
Sample Collection
A small blood sample is collected, often from a finger prick or a small blood draw.
Application to Test Device
The blood sample is placed on a test strip or device within the HBsAg rapid test kit.
Reagent Reaction
The kit contains reagents that react with HBsAg, forming a visible line or symbol if HBsAg is present.
Interpretation of Results
Results are generally available within 10-20 minutes. A positive result indicates that HBsAg is detected in the blood sample, while a negative result suggests that no HBsAg is present.

Allow the test device, specimen, buffer, and/or controls to equilibrate to room temperature (15-30°C) prior to testing.
》Remove the test device from the sealed foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed immediately after opening the foil pouch.
》For Serum or Plasma specimen: Hold the dropper vertically, transfer 3 drops of serum or plasma (approximately 75 μL) to the specimen well (S) of test device and then start the timer. See illustration below. For Venipuncture Whole Blood specimen:
Hold the dropper vertically, transfer 3 drops of venipuncture whole blood (approximately 75 μL) to the specimen well (S) of test device, then add 1 drop of buffer (approximately 40 μL) and start the timer. See illustration below.
For Fingerstick Whole Blood specimen:
• To use a capillary tube: Fill the capillary tube, transfer approximately 75 μL of fingerstick whole blood specimen to the specimen well (S) of test device, then add 1 drop of buffer (approximately 40 μL) and start the timer. See illustration below.
• To use hanging drop: Allow 3 hanging drops of fingerstick whole blood specimen (approximately 75 μL) to the specimen well (S) of test device, then add 1 drop of buffer (approximately 40 μL) and start the timer. See illustration below.
》Wait for the colored line(s) to appear. The result should be read at 15 minutes. Do not interpret the result after 30 minutes.
Reading The Test Results
Positive
Both purplish read test band and purplish read control band appear on the membrane. The lower the antibody concentration, the weaker the test band.
Negative
Only the purplish red control band appears on the membrane. The absence of a test band indicates a negative result.
Invalid
There should always be a purplish red control band in the control region regardless of test result. If control band is not seen, the test is considered invalid. Repeat the test using a new test device.
》Do not use the test kit beyond the expiration date.
》Do not use the kit if the pouch is punctured or not well sealed.
》For in vitro use only. Do not swallow.
》All specimens from the body should be treated as potentially infectious.
》Contaminated blood may give incorrect test results.
》Discard after first use. The test cannot be used more than once.
DISPOSAL: The used device has the risk of infection. Please dispose all used contents properly.

FAQ
As one of the most professional inflammatory test kit manufacturers and suppliers in China, we're featured by quality products and good price. Please rest assured to buy cheap inflammatory test kit in stock here from our factory.
CRP Test Kit, Dengue IgG IgM Test Kit, Dengue NS1 Test Kit