Product Advantages
Stable results
The results can clearly reflect the average blood glucose level over the past 2 or 3 months.The test can be started at any time and anywhere, which is convenient for patients who need long-term blood glucose management.
Convenient operation
The microfluidic fluorescence immunoassay technology provide instant detection within ten minutes, which is fast and convenient.
Accurate detection
The reaction system is equipped with the double antibody sandwich method and the microfluidic chip technology,which provides accurate results and consistent clinical detection.
Strong adaptability of samples
The sample processing is very flexible and can easily adapt to different situations.
5.Intelligent supporting instruments
The LYOFIA series fluorescence analyzer supports automatic scanning, result calculation and output, which helps to reduce human mistakes.
Our company offers the Poctell® series of HbA1c Test Kit (with multiple models to choose from and customization supported). Welcome your bulk purchases and inquiries.

TEST PROCEDURE

Interpretation of Results

POSITIVE:*
* A colored band appears in the control band region (C) and another colored band appears in the T band region.

NEGATIVE: One colored band appears in the control band region (C). No band appears in the test band region (T).

Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.
Note: The reference value of this reagent is only established specific to clinical trial samples. It is recommended that laboratories establish actual reference ranges according to the population, age, gender, diet and other conditions in different regions.
Performance Characteristic
Sensitivity and Specificity
The HbA1c Rapid Test Device (Whole Blood) was compared with other device;the results show that The HbA1c Rapid Test Device (Whole Blood) has a high sensitivity and specificity.
The HbA1c Rapid Test Device (Whole Blood) vs. other device
|
Method |
other device |
Total Results |
||
|
The HbA1c Rapid Test Device (Whole Blood) |
Results |
Positive |
Negative |
|
|
Positive |
55 |
1 |
56 |
|
|
Negative |
0 |
425 |
425 |
|
|
Total Results |
55 |
426 |
481 |
|
Note: <6.0% means negative result; >6.0% means positive result.
Relative Sensitivity: 100% (93.4%-100.0%) *
Relative Specificity: 99.8% (98.7%-99.9%)*
Packing and Transportation
All products are professionally packaged, wrapped with foam paper or foam padding for protection and safe storage. We also support both land and air freight delivery to meet diverse logistics needs.


About Us
INNOCHEK BIOTECH CO., LTD, are dedicating in delivering comprehensive, efficient, and innovative POCT solutions to global users. The company was stablished in 2017 and headquartered in Hongkong, is a conglomerate seamlessly integrating R&D, production, registration, sales, OEM and marketing. Leveraging microfluidics and electrochemical technologies, INNOCHEK has successfully developed a diverse range of key products, including blood gas and electrolytes, immunofluorescence, coagulation, and animal diagnostic series.



We have all necessary certificates like CE, ISO, FSC, etc.
Hot Tags: glycosylated hemoglobin (hba1c) test kit, China glycosylated hemoglobin (hba1c) test kit manufacturers, suppliers, factory, Blood Insulin Test Kit, C peptide Test Kit, diabetes poct, HbA1c Test Kit, Microalbumin Test Kit