video
Multi-Drugs Test Cup

Multi-Drugs Test Cup

PocTell® Multi-Drugs Test Cup, Multi-Drugs Test Panel is a rapid visual immunoassay for the qualitative, presumptive detection of drugs of abuse in human urine specimens .

Product Introduction

INTENDED USE

 

PocTell® Multi-Drugs Test Cup, Multi-Drugs Test Panel is a rapid visual immunoassay for the qualitative, presumptive detection of drugs of abuse in human urine specimens .

Multi Drugs Test Cup Panel
Multi Drugs Test Cup

 

Ordering Information

 

Test Item

Format

Specimen

Reaction Time

Cut-off

Shelf life

Kit Size

DOA

Panel

Cup

Urine

5 mins

IFU

24 months

25T/Kit

 

TEST PRINCIPLE

 

PocTell® Multi-Drugs Test Cup, Multi-Drugs Test Panel Device detects drugs of abuse through visual interpretation of color development on the internal strip. Drug conjugates are immobilized on the test region of the membrane. During testing, the specimen reacts with antibodies conjugated to colored particles and precoated on the sample pad. The mixture then migrates through the membrane by capillary action, and interacts with reagents on the membrane. If there are insufficient drug molecules in the specimen, the antibody-colored particle conjugate will bind to the drug conjugates, forming a colored band at the test region of the membrane. Therefore, a colored band appears in the test region when the urine is negative for the drug. If drug molecules are present in the urine above the cut-off concentration of the test, they compete with the immobilized drug conjugate on the test region for limited antibody binding sites. This will prevent attachment of the antibody-colored particle conjugate to the test region. Therefore, the absence of a colored band at the test region indicates a positive result. The appearance of a colored band at the control region serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking has occurred.

 

-2

DIRECTIONS FOR USE

 

Bring tests, specimens and/or controls to room temperature (15-30°C) before use.

1.Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.

2.Place the test device on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 100 L) to the specimen well (S) of the test device, and then start the timer. Avoid trapping air bubbles in the specimen well (S).

3.Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

Hot Tags: multi-drugs test cup, China multi-drugs test cup manufacturers, suppliers, factory, COT Rapid Test, Dia Rapid Test, MQL Rapid Test, PPX Rapid Test, THC Rapid Test, Tramadol TML Rapid Test

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag